Tap Drill Sizes: Chart for M1.6–M24 and Fine Metric Threads

Updated

In short

The hole size for a cut metric thread is approximately the nominal diameter minus the pitch: d = D − P (e.g. M6 – 5.0 mm, M8 – 6.8 mm, M10 – 8.5 mm, M12 – 10.2 mm). This size lies within the ISO 965 6H minor diameter zone. Form (roll) taps need a larger hole of roughly D − 0.5 × P, with the exact value given by the tap manufacturer.

A tap drill size is the diameter of the hole that must be drilled before cutting an internal thread with a tap. Too small a hole increases tapping torque and the risk of tap breakage; too large a hole reduces thread depth and strength. For ISO metric threads a simple rule is used:

d drill ≈ D − P

where D is the nominal thread diameter (mm) and P the pitch (mm). For example, M10 (P = 1.5): 10 − 1.5 = 8.5 mm. For the threads themselves see metric threads.

Why D − P?

The basic minor diameter of an internal thread per ISO 724 is D1 = D − 1.0825 × P, and ISO 965-1 allows it to grow by the tolerance TD1. A D − P hole is slightly larger than the minimum D1, so the tap does not have to cut the minor diameter, yet it still falls within the 6H zone. For example, M6-6H: D1 = 4.917–5.153 mm, drill 5.0 mm. In US practice this corresponds to roughly 75–77 % thread depth, which is practically as strong as a full thread but much easier to tap.

Coarse-pitch threads

ThreadPitch P, mmD1 min, mmD1 max (6H), mmDrill, mm
M1.60.351.221–1.25
M20.41.567–1.6
M2.50.452.013–2.05
M30.52.4592.5992.5
M40.73.2423.4223.3
M50.84.1344.3344.2
M614.9175.1535.0
M81.256.6476.9126.8
M101.58.3768.6768.5
M121.7510.10610.44110.2
M14211.83512.21012.0
M16213.83514.21014.0
M182.515.29415.74415.5
M202.517.29417.74417.5
M222.519.29419.74419.5
M24320.75221.25221.0

For the smallest threads (M1.6–M2.5) the drill is chosen near the lower limit because the thin tap core is very sensitive to torque; check their tolerances in ISO 965.

Fine-pitch threads

ThreadD1 min, mmD1 max (6H), mmDrill, mm
M8×16.9177.1537.0
M10×1.258.6478.9128.8
M10×18.9179.1539.0
M12×1.510.37610.67610.5
M12×1.2510.64710.91210.8
M14×1.512.37612.67612.5
M16×1.514.37614.67614.5
M18×1.516.37616.67616.5
M20×1.518.37618.67618.5
M22×1.520.37620.67620.5
M24×221.83522.21022.0

Form (roll) taps

A form tap produces no chips – it displaces material into the thread profile, so the hole must be larger. An approximate rule is d ≈ D − 0.5 × P: M3 – ~2.8 mm, M4 – ~3.7 mm, M5 – ~4.6 mm, M6 – ~5.5 mm, M8 – ~7.4 mm, M10 – ~9.3 mm, M12 – ~11.2 mm. Hole size is critical in forming (often ±0.05 mm), so always use the value recommended by the tap manufacturer. Forming suits ductile materials such as aluminium, low-carbon and stainless steel, but not cast iron or brittle materials. See taps.

Blind hole depth

The start of a tap has a chamfered lead that does not cut a full profile. Blind holes typically use form C taps (2–3 pitch chamfer), so:

drill depth ≈ thread length + (3…5) × P + chip allowance

Example: M8 with 16 mm of full thread required. 16 + 4 × 1.25 = 21 mm → drill Ø6.8 mm to about 21–22 mm full-diameter depth, not counting the 118° or 140° drill point.

Speed and feed when tapping

When tapping, feed per revolution equals the pitch: F = n × P, and spindle speed is calculated as usual: n = (Vc × 1000) / (π × D). Example: M8, HSS tap in steel, starting Vc = 10 m/min → n = 10000 / (π × 8) ≈ 400 rpm, F = 400 × 1.25 = 500 mm/min. This is only a starting value – the manufacturer's data takes priority. See cutting speed and RPM.

Practical tips

  • In hard and gummy materials (stainless steel, titanium) a drill 0.05–0.1 mm larger can be used if the 6H zone allows it.
  • Countersink the hole entry at 90° to the nominal diameter – the tap starts more easily and no burr is raised.
  • For large, expensive workpieces consider thread milling: a broken tap can scrap the part.
  • For drill size series see standard drill sizes.

Tapping and drilling service providers can be found on the CNC Pasaulis marketplace.

Frequently asked questions

What drill size is used for an M6 tap?

An M6 thread (P = 1 mm) uses a 5.0 mm drill. A form tap needs a hole of about 5.5 mm; the exact value is given by the manufacturer.

What drill size is used for an M8 tap?

For M8 coarse (1.25 mm pitch) use a 6.8 mm drill; for fine M8×1 use a 7.0 mm drill.

What is the formula for tap drill size?

For cut metric threads d ≈ D − P, where D is the nominal diameter and P the pitch. For example M12: 12 − 1.75 = 10.25, so a 10.2 mm drill is used in practice.

Why does a form tap need a larger hole?

A form tap does not cut but displaces material, which fills the thread crests. If the hole is too small there is too much material and the tap can break, so the hole is about D − 0.5 × P.

How much deeper should a blind hole be drilled?

Typically 3–5 pitches deeper than the required full thread, depending on the tap chamfer form, plus some room for chips.

Looking for someone to do this job? Find a manufacturer on the marketplace or post a request.

Services offered I need a service