Siemens SINUMERIK Alarms: Number Ranges, Common Alarms and Clearing
Updated
SINUMERIK alarms are control messages whose number range identifies the source: 010000–019999 channel, 020000–029999 axis and spindle, and 400000–799999 PLC and machine builder alarms. Each alarm has a clearing condition (Cancel key, RESET or power on), and the SINUMERIK Diagnostics Manual for the software version gives the exact meaning and remedy.
A SINUMERIK alarm is a message from a Siemens CNC control (such as 840D sl or 828D) about an error or condition that stops the program, inhibits the axes or simply warns the operator. An alarm consists of a number, a text with parameters (channel, block, axis) and a clearing condition. The number alone tells you which part of the system raised it. Alarm texts can vary between software versions, so the SINUMERIK Diagnostics Manual for the specific version is the authoritative source.
Reading alarms on the HMI
The active alarm appears in the header line of the screen. More detail is available in the Diagnostics operating area:
- Alarm list – all currently active alarms with number, date, time, text and a clearing condition symbol.
- Messages – PLC operator messages that do not stop operation but report a status.
- Alarm log – history of incoming and outgoing alarms with timestamps, useful for finding recurring or intermittent faults.
In many versions, selecting an alarm in the list opens a help text with an explanation and recommended remedy. The channel, block number and axis given in the alarm text are worth noting down.
Clearing conditions
Each alarm has a defined clearing condition, shown as a symbol in the list. The main ones are:
- Cancel key – the alarm is informational; acknowledge it and continue.
- RESET – remove the cause and press RESET; the program in the channel is aborted.
- POWER ON – the alarm only clears after switching the control off and on (e.g. after changing certain machine data or a hardware fault).
- Self-clearing – the alarm disappears once the cause is removed (e.g. many PLC alarms).
If an alarm returns immediately after RESET, the cause is still present – repeating the reset will not help.
Alarm number ranges
| Number range | Alarm group |
|---|---|
| 000000–009999 | General alarms |
| 010000–019999 | Channel alarms (program, limits, block preparation) |
| 020000–029999 | Axis and spindle alarms |
| 030000–099999 | Functional alarms |
| 060000–064999 | Siemens cycle alarms |
| 065000–069999 | User cycle alarms |
| 400000–499999 | General PLC alarms |
| 500000–599999 | Channel PLC alarms |
| 600000–699999 | Axis and spindle PLC alarms |
| 700000–799999 | User area – machine builder PLC alarms |
Alarms from 700000 are defined in the machine builder's PLC program (for example door, lubrication, coolant or tool changer conditions), so look them up in the machine documentation rather than the Siemens manual.
Common alarms
| Number | Meaning | Typical cause | What to check |
|---|---|---|---|
| 3000 | Emergency stop | Emergency stop button pressed or safety circuit open | Buttons, doors, safety circuit; then RESET |
| 10630 | Axis at working area limit | Motion beyond the defined working area limitation | Work offset, tool offsets, working area limits |
| 10720 | Software limit switch | Programmed position beyond the software limit | Program coordinates, work offset, tool length |
| 12080 | Syntax error in text | Invalid block syntax | The indicated block and text, post-processor output |
| 25000 | Hardware fault, active encoder | Encoder signal lost or disturbed | Encoder cable, connectors, shielding; call service |
| 25040 | Standstill monitoring | Axis drifted beyond tolerance at standstill | Brakes, counterbalance, external forces, mechanics |
| 25050 | Contour monitoring | Axis does not follow the commanded contour within tolerance | Binding, lubrication, load, drive status |
| 25060 | Speed setpoint limitation | Drive stays at the speed setpoint limit for too long | Mechanical load, drive faults, encoder |
| 25201 | Drive fault | The SINAMICS drive reports a fault | The drive fault list (F/A messages) |
For limit alarms the axis can usually be jogged back in the opposite direction; coordinate systems are explained in CNC machine axes and coordinates. Knowing G-code basics and M-codes helps avoid syntax errors, although Siemens controls also have their own commands and high-level language elements.
Drive faults (SINAMICS)
The SINAMICS drives used with SINUMERIK have their own message system: F marks faults, which switch the drive off, and A marks alarms (warnings), which do not necessarily stop operation. In the control alarm list these appear as 2xxxxx numbers. Often an axis alarm (such as 25201) and a related drive message appear together – the cause is found in the drive message, described in the SINAMICS List Manual.
Practical diagnostic checklist
- Write down the numbers, texts, channel, block and axis of all active alarms.
- Use the number range to identify the source: channel, axis, cycle, PLC or machine builder.
- Check the alarm log for the first alarm that appeared – usually the root cause.
- For axis alarms, review related drive messages.
- Remove the cause before RESET; do not reset repeatedly.
- For axis monitoring alarms, check mechanics, lubrication, load and cables first.
- Do not change machine data (tolerances) just to suppress an alarm.
Safety note
Work on the electrical cabinet, drives and cables must only be done by qualified staff: the drive DC link stays charged after power-off. Never bypass the emergency stop circuit or guards.
Fanuc codes are covered in Fanuc alarm codes. Machine repair and service specialists can be found or requested on the CNC Pasaulis marketplace.
Frequently asked questions
How can I tell where a SINUMERIK alarm comes from by its number?
The range shows the source: 010000–019999 channel, 020000–029999 axis and spindle, 060000–069999 cycles, 400000–699999 PLC and 700000–799999 machine builder alarms.
Why does an alarm not clear with RESET?
Either the cause is still present, or the alarm's clearing condition is POWER ON, in which case the control must be switched off and on.
What does alarm 3000 mean?
Emergency stop: an emergency stop button was pressed or the safety circuit is open. Once released, the alarm is cleared with RESET.
Where do I find the meaning of 700000-series alarms?
They are defined by the machine builder in its PLC program, so their meanings are in the machine documentation.
What is the difference between F and A drive messages?
F is a drive fault that normally switches the drive off; A is a warning that does not necessarily stop operation. The control shows them as 2xxxxx numbers.
Looking for someone to do this job? Find a manufacturer on the marketplace or post a request.
Services offered I need a service