Fanuc Alarm Codes: Structure, Common Alarms and What to Check
Updated
A Fanuc alarm is a control message that the program or machine cannot continue; on Series 0i-D, 0i-F and 30i controls the code consists of a type prefix (PS, SV, OT, DS and others) and a number, such as PS0010 or SV0410. Program alarms (PS) are usually cleared by correcting the program and pressing RESET, while servo, overtravel and encoder alarms require finding the mechanical or electrical cause.
A Fanuc alarm is a message from the CNC control indicating an error that stops program execution or prevents the machine from moving. The alarm code identifies the type and number of the error, and a short English text describes it. This article explains how alarm codes are structured and lists the most common ones. Message wording can differ slightly between control series and software versions, so the Fanuc maintenance and operator manuals for the specific control are always the authoritative source.
Reading the alarm screen
When an alarm occurs, the control usually switches to the alarm screen automatically and ALM flashes at the bottom of the display. The alarm list can be opened with the MESSAGE key (ALARM on some panels). It shows the code, the text and, for many alarms, the axis or block concerned. The operator message page next to it shows messages issued by the machine builder. The alarm history (HISTORY) stores earlier alarms with date and time – very useful for tracking recurring or intermittent faults, so note the last few entries before calling a service technician.
Alarm code structure
On Series 0i-D, 0i-F and the 30i family, the number is preceded by a two-letter type prefix:
| Prefix | Alarm type |
|---|---|
| PS | Program and operation alarms (syntax, offsets, memory) |
| BG | Background edit alarms |
| SR | Communication (data transfer) alarms |
| PW | Alarms requiring power off and on (typically after a parameter change) |
| IO | Memory and file alarms |
| SV | Servo alarms |
| OT | Overtravel alarms |
| OH | Overheat alarms |
| SP | Spindle alarms |
| DS | Other alarms (e.g. absolute pulse coder) |
| EX | Machine builder PMC alarms |
Older controls such as 0i-C and 18i show only a number without a prefix, for example 010, 401 or 500. These broadly correspond to the newer codes (010 improper G-code, 401 servo V-ready off, 500 overtravel in the plus direction). Machine builder PMC messages (EX or 1000–1999 alarms and 2000–2999 operator messages) are defined by the machine builder, so look them up in the machine manual.
Common alarms
| Code and message | Typical cause | What to check |
|---|---|---|
| PS0003 TOO MANY DIGIT | A value has more digits than the address allows | Block values, a missing decimal point |
| PS0004 ADDRESS NOT FOUND | A number or sign without an address letter at the start of a block | Missing letter (X, Y, Z, F etc.) |
| PS0005 NO DATA AFTER ADDRESS | An address is not followed by a value | Incomplete words, e.g. X without a number |
| PS0006 ILLEGAL USE OF NEGATIVE SIGN | Minus sign in an invalid position | Sign position, addresses that do not accept negatives |
| PS0007 ILLEGAL USE OF DECIMAL POINT | Decimal point where not allowed | Addresses that accept integers only |
| PS0009 IMPROPER NC-ADDRESS | An address unknown to or not allowed by the control | Post-processor output, typing errors |
| PS0010 IMPROPER G-CODE | Unusable G-code or function option not installed | The G-code, control options |
| PS0011 FEED ZERO (COMMAND) | No feed F for a cutting move, or F0 | Whether an F value precedes G01/G02/G03 |
| PS0020 OVER TOLERANCE OF RADIUS | Difference between arc start and end radius exceeds the limit | I, J, K or R values, arc end point |
| PS0029 ILLEGAL OFFSET VALUE | Invalid offset value | The offset table |
| PS0030 ILLEGAL OFFSET NUMBER | Invalid offset number (D, H) | D/H numbers and number of offsets available |
| PS0033 NO SOLUTION AT CRC | No intersection can be found in cutter radius compensation | Contour geometry, lead-in and lead-out moves |
| PS0041 INTERFERENCE IN CRC | Radius compensation would cause overcutting | Tool radius versus inside radii and steps |
| PS0070 NO PROGRAM SPACE IN MEMORY | Program memory full | Delete unused programs, use external storage |
| PS0071 DATA NOT FOUND | Searched program number or block not found | The program or block number |
| PS0073 PROGRAM NUMBER ALREADY IN USE | That program number already exists in memory | Rename or delete the old program |
| OT0500 / OT0501 + / – OVERTRAVEL (SOFT 1) | Stored (software) stroke limit exceeded in plus / minus direction | Work offset, tool length, program coordinates |
| OT0506 / OT0507 + / – OVERTRAVEL (HARD) | Axis limit switch tripped | Why the axis passed the software limit |
| SV0401 IMPROPER V_READY OFF | Servo amplifier ready signal dropped | Emergency stop circuit, amplifier status and alarms |
| SV0410 EXCESS ERROR (STOP) | Position error too large at standstill | Brakes, vertical axis counterbalance, mechanics |
| SV0411 EXCESS ERROR (MOVING) | Position error too large during motion | Binding, lubrication, load, cables |
| SV0436 SOFTTHERMAL (OVC) | Motor overloaded for too long (calculated thermal overload) | Cutting conditions, friction, brakes, mechanics |
| DS0300 APC ALARM: NEED REF RETURN | Absolute pulse coder has lost its position | Perform reference return per the machine procedure |
Program alarms
PS alarms usually come from manual programming mistakes, an unsuitable post-processor or programs transferred from another machine. The control stops at the block where it detected the error, but the cause can be in an earlier block (for example a missing feed or radius compensation lead-in). After correcting the program, clear the alarm with RESET. For program structure see G-code basics and M-codes.
Overtravel
The software limit (SOFT 1) is the permitted travel range set in parameters. After the alarm, press RESET and jog the axis (JOG or handwheel) in the opposite direction, then find out why it was exceeded: wrong work offset, tool length offset or coordinates. Coordinate systems are explained in CNC machine axes and coordinates.
A hard overtravel (HARD) means the limit switch has tripped. On many machines the axis can only be moved off the switch while holding an overtravel release button, or by another procedure specified by the builder – always follow the machine manual and move slowly in the opposite direction.
Servo alarms
SV alarms indicate that the drive cannot follow the commanded position or the motor is overloaded. Do not press RESET repeatedly – this can overheat the motor or worsen mechanical damage. First check whether the axis is binding, lubrication works, the ball screw and guideways are undamaged, there are no signs of a collision and the motor and encoder cable connectors are secure. On vertical axes, an alarm at standstill can be caused by a brake or counterbalance fault.
Encoder battery and reference return
Machines with absolute pulse coders (APC) retain axis positions with the power off, using batteries. When the battery voltage drops, the control shows a battery-low warning, and the batteries should be replaced promptly. If the voltage falls to zero, the position is lost (for example DS0306 APC ALARM: BATTERY VOLTAGE 0) and DS0300 appears – the reference position must be set again. Replace the batteries with the control powered on (usually with emergency stop pressed), otherwise the position will be lost. The machine builder specifies the exact procedure and battery type.
Safety note
Work on the electrical cabinet, servo amplifiers and cables must only be done by qualified staff: amplifier capacitors stay charged after power-off. Never bypass limit switches or guards.
Practical diagnostic checklist
- Write down the exact code, text, axis and block.
- Check the alarm history for repeats.
- Identify the type from the prefix: program (PS), overtravel (OT), servo (SV), encoder (DS) or builder PMC (EX).
- Fix program errors in the program, not in parameters.
- For servo alarms, check mechanics, lubrication, load and cables first.
- Look up builder alarms in the machine manual.
- If the cause is unclear, contact a service technician with the information collected.
The equivalent Siemens codes are covered in SINUMERIK alarms. Machine repair and service specialists can be found or requested on the CNC Pasaulis marketplace.
Frequently asked questions
What do the letters PS, SV or OT before a Fanuc alarm number mean?
They give the alarm type: PS is a program or operation error, SV a servo alarm and OT an overtravel. These prefixes are used on Series 0i-D, 0i-F and 30i controls.
How do I clear a PS program alarm?
Find the error in the indicated or a preceding block, correct the program and press RESET. Some alarms (PW) require switching the power off and on.
How do I recover from an OT overtravel alarm?
After a software limit alarm, press RESET and jog the axis in the opposite direction. After a hard limit, follow the machine builder's procedure, often using an overtravel release button.
Why should I not keep pressing RESET after a servo alarm?
Servo alarms often indicate mechanical overload or binding. Resetting repeatedly without removing the cause can overheat the motor or increase damage.
Why must encoder batteries be replaced with the power on?
The control power keeps the absolute encoder position during replacement. Replacing them with the power off can lose the position and require a new reference setting.
Where do I find the meaning of EX or 1000–2999 alarms?
They are defined by the machine builder in its PMC program, so their meanings are in the machine manual, not the Fanuc control manual.
Looking for someone to do this job? Find a manufacturer on the marketplace or post a request.
Services offered I need a service